Item                              Model unit KLCV-400 KLCV-600 KLCV-1200
Drying chamber mm 1650Φ × 2600L 1850Φ × 3200L 2050Φ × 4700L
Material   SS400 SS400 SS400
Cover of chamber   Hinged screw front cover
Shelf area m2 36 54 108
Fixed effective layers   16 18 20
Shelf spacing mm 75 75 75
Plate tray  mm 520W × 1080L × 25H 5250W ×960L × 25H 650W × 1080L × 25H
Quantity of tray   64 108 160
Heat transfer area m2 70 110 180
Circulating pump kW 2.2 3.7 5.6
Heater kW 24 36 ---
Condenser mm 1650Φ × 2200L 1850Φ × 2800L 2050Φ × 4000L
Temperature   -40~-50 -40~-50 -40~-50
Condensing capacity  kg/H2O 400 600 1200
Refrigerator kW 37.5 56 56 × 2
vacuum pump kW 3.75 × 2 5.5 × 2 7.5 + 11
Cooling water pump kW 3.7 5.6 5.6 × 2
Electrical apparatus   Torr vacuometer and electronic thermometer
Summary of system
Horsepower 220V~380V kW 60 90 160
Eelectrical heater kW 24 36 ---
or 5kg/cm2G steam Kg/hr 100 150 300
Water quantity for operating m3/cir 2 3 6
Install area  m2 100 120 200
Item                              Model unit KLCV-10 KLCV-50 KLCV-100 KLCV-200
Drying chamber mm 650Φ × 700L 1050Φ × 1200L 1250Φ × 1450L 1450Φ × 1750L
Material   SUS 304 SS400 SS400 SS400
Cover of chamber   Screw front cover
Shelf area m2 0.9 4.5 9 18
Fixed effective layers   3 8 12 14
Shelf spacing mm 85 75 75 75
Plate tray mm 500W × 600L × 25H 650W × 850L × 25H 700W × 1080L × 25H 700W × 920L × 25H
Quantity of tray   3 8 12 28
Heat transfer area m2 1.8 9 18 36
Circulating pump kW 0.37 0.75 1.5 2.2
Heater kW 4 10 14 18
Condenser mm 650Φ × 700L 1050Φ × 1200L 1250Φ × 1400L 1450Φ × 1700L
Temperature   -40 ~ -50 -40 ~ -50 -40 ~ -50 -40 ~ -50
Condensing capacity kg/H2O 10 50 100 200
Refrigerator kW 3 15 22 30
Blower kW 0.75 1.5 2.2 2.2
Vacuum pump kW 1.5 2.2 3 1.5 + 3.7
Cooling water pump kW 0.37 0.75 1.5 2.2
Electrical apparatus   Torr vacuometer and electronic thermometer
Summary of system
Horsepower 220V~380V kW 8.9 21 32 43
Electrical heater kW 4 10 14 18
Water quantity for operating m3/cir 0.3 0.8 1.5 2
Install area m2 4 12 18 50
       Remarks:
  • As table described above, vacuum freeze-drying units are standard specifications. Welcome to order special specifications.
  • Specifications are subject to change without notice for further improvement.

>>Specifications table of vacuum freeze-drying units
CopyrightÒ 2007, R&D Department, Kuenling Refrigerating Machinery Co., LTD.,  Last updated: 2007.8.14
________________________________________________________________
Home   |   About us   |   Products   |   Technology   |   Contact   |   Feedback
Home   |   About us   |   Products   |   Technology   |   Contact   |   Feedback   |   中文網頁